Razvoj i primena tehničkih dijagnostičkih metoda i opreme za praćenje i vođenje procesa; unapređenje opreme sa aspekta procesa koji se u njima odvijaju; savremena organizacija proizvodnje, metode i sredstva održavanja opreme.
Radovi odabrani za sesiju Konferencije pod nazivom: EKSPLOATACIONI PROBLEMI TERMO/HIDRO/VETRO I DRUGIH ELEKTRANA
Aleksandar Petkovic (Lecturer, Academy of Applied Studies “Polytechnic”, Belgrade)
Jovan Ilic (PhD student, University of Belgrade, Faculty of Mechanical Engineering, Belgrade)
Nikola Tanasic (Professor, Academy of Applied Studies “Polytechnic”, Belgrade)
Abstrakt
Cooling water systems of generating units (turbine-generator sets) are one of the most important auxiliary systems at hydropower plants. Their function is to assure prerequisites for unrestricted long-term operation of the generating units under all exploitation circumstances (i.e. number of generating units in operation, their operating power, during all seasons of the year). For each possible conceptual solution of the cooling water systems (joint, group, individual) and each possible manner of providing water streaming (pumping from tailwater, intaking from turbine spiral casings followed by ejector jet pumping or by pressure reducing) pipe networks of these systems are structurally and hydraulically complex, branched and looped, arrangements. Aside of topological complexity, these systems are characterized by presence of various constellations of exploitation regimes and numerous items of equipment (pumps, filters, regulating/shut-off valves, heat exchangers, measuring devices), fittings (bends, branches, converging/diverging pieces) and pipe reaches, which technical characteristics are to be comprehensively selected (varied and finally adopted) within design stage. For that reason, these systems cannot be easily and conveniently analyzed by “traditional” methods (analytical and/or graphical matching of pump and pipeline operating curves) due to demanding and error-prone efforts. In such conditions, it is much more expedient to apply numerical tools, i.e. softwares with graphic user interface for easy determination of the system topology and entering/modifying of the structural and hydraulic characteristics of the system elements, with clear overview of the obtained results (i.e. flow and pressure distribution) at any point of the system. Softwares for numerical analyses of hydraulic networks have been used in worldwide practice for more than 30 years. The paper presents the results of conducting numerical analyses of cooling water systems in EPANET software for the case study of HPP Vrla 1 (of 4 x 14 MW installed output).
Srđan Milić, Đorđe Petković, Dejan Đukanović, Nikola Marković, Teodora Madžar, Milan V. Petrović (University of Belgrade, Faculty of Mechanical Engineering, Belgrade)
Abstrakt
The new unit B3 at the Kostolac Thermal Power Plant began operation in September 2024 after a trial period. The new unit has supercritical live steam parameters of 242 bar and 566 oC and a gross power of 350 MW. The equipment manufacturer provided guarantees for the value of gross power, gross and net unit efficiency and share of the unit’s own consumption. Acceptance tests were conducted by the Laboratory of Thermal Turbomachinery - Faculty of Mechanical Engineering in Belgrade according to the ASME PTC 46 standard in October 2024. The paper presents the requirements of the standard for testing the new unit, as well as the approach to determining the share of own consumption and correction of test results. For comparing measured values with guaranteed values, measurement uncertainty is taken into account and the paper will present the procedure for determining measurement uncertainty.
Dejan Cvetinović, Aleksandar Erić ("VINCA" Institute of Nuclear Sciences, National Institute of the Republic of Serbia, Laboratory for Thermal Engineering and Energy, University of Belgrade, Belgrade, Serbia)
Abstrakt
The lignite-fired supercritical unit with a rated generator output of 350 MW was newly built at the Thermal Power Plant "Kostolac B" (TE-KO B3). The TPP "Kostolac B" is located on the right bank of the river Mlava, about 12 km from Požarevac. The lignite comes from the Drmno open pit mine, which is located to the west of the power plant TE-KO. TE-KO is a single state-owned company managed by the "Electric Power Industry of Serbia" (EPS) and produces coal, electricity and heat. The power plant is brand new and was designed, supplied and commissioned by CMEC, China.
Performance tests of boiler and mills were provided according to the following standards:
1. Steam generator efficiency according to the standard ANSI/ASME PTC 4 -2013.
2. ASME PTC 4.3 - Air heaters
3. Mills performance measurements by separate measurements, at mills maximal load, in accordance to ANSI/ASME PTC 4.2-1969 (R2016) Performance Test Code - Coal Pulverizers.
Performance tests of emissions were provided according to the following national laws, regulations and standards:
1. Law on Environmental Protection (“Official Gazette of the Republic of Serbia”, No. 135/04, 36/09, 43/11 and 14/16, 76/2018, 95/2018 – other Laws and 95/2018 - other Laws)
2. The Regulation on limiting values of emissions of polluting materials into the air from the combustion plants, (“Official Gazette of the Republic of Serbia”, No. 6/2016 and 67/2021)
3. The Regulation on measurements of emissions of polluting substances into the air from stationary sources of pollution (“Official Gazette of the Republic of Serbia”, No. 5/2016)
4. Amendment on the Regulation on measurements of emissions of polluting substances into the air from stationary sources of pollution (“Official Gazette of the Republic of Serbia”, No. 10/2024)
5. For sound level measuring, it is required to use high-precision devices that meet the requirements of the specifications from the Publication SRPS EN 61672-1:2015 “Electroacoustics - Sound level meters - Part 1: Specifications”, and IEC 60651:1979, ED1 “Sound level meters”, Class 1.
The test performer is the accredited laboratory of the “Vinča” Institute of Nuclear Sciences, Belgrade.
This paper presents results of this complex field measurements that provided good base for performance assesment.
Vladimir B. Živković, Slađana L. Florić, Dragan I. Tomanić, Miroslav V. Kljajić (Naučno-tehnološki centar, Naftna industrija Srbije, Termoelektrana „Nikola Tesla B”, Elektroprivreda Srbije, Fakultet tehničkih nauka, Univerzitet u Novom Sadu)
Abstrakt
Predmet istraživanja ovog rada je analiza kritičnih brzina rotora parne turbine termoelektrane „Nikola Tesla B” instalisane snage 650 MW, dobijena primenom frekventne metode konačnih elemenata (FEM). Model turbine je razmatran u potpuno termički progrejanom stanju kako bi se u obzir uključili realni uslovi eksploatacije. Dobijeni rezultati numeričke frekventne FEM analize upoređeni su sa rezultatima vibrodijagnostičkih merenja sprovedenih na samoj turbini, kao i sa referentnim podacima o kritičnim brzinama proizvođača turbine. Analiza u najvećem delu pokazuje visok stepen slaganja između simulacija i eksperimentalnih rezultata, pri čemu su uočena i određena odstupanja od vrednosti evidentiranih od strane Distribuiranog sistema upravljanja u kontrolnoj sobi termoelektrane. Ishod istraživanja je sveobuhvatan uvid u kritične brzine svakog rotora, jasno prikazujući njihove dinamičke interakcije kada se uporede sa dijagramima i sumarnim signalima relativnih vibracija rotora. Rezultat ne samo da doprinosi boljem razumevanju složenih vibracionih fenomena u parnim turbinama velikih snaga, već i predstavlja praktičan alat koji inženjerima može poslužiti u budućim postupcima dijagnostike, optimizacije i planiranja prediktivnog održavanja.
Jovan Ilić (Elektroprivreda Srbije Belgrade JSC, Belgrade)
Aleksandar Petković (Academy of Applied Studies )
Đorđe Koković (Elektroprivreda Srbije Belgrade JSC, Belgrade)
Abstrakt
Hydropower plants play a vital role in the power system, as their operational flexibility and relatively fast synchronization to the grid allow them to cover peak loads in the electricity demand curve. However, depending on the configuration and technical characteristics of a hydropower facility - from the reservoir and intake structures, through the type of turbine-generator units and grid connection point, to the outlet structures - certain operational limitations may arise. The objective of this paper is to explain the role of hydropower plants in the power system, particularly in the context of the intensive integration of variable renewable energy sources, with special attention to the features of hydropower facilities that affect performance in tertiary frequency control. Although solar and wind power plants are environmentally sustainable sources of energy, their variability introduces imbalances into the power system. Consequently, the operational flexibility of hydropower plants, which contribute to system stability through the provision of ancillary services, has gained increasing importance. This paper presents the case study of the Bistrica Hydropower Plant, illustrating the principles of plant dispatch, unit capabilities, and constraints resulting from the facility’s technical characteristics.
Žarko Nestorović (Elektroprivreda Srbije AD Beograd, Ogranak Đerdap)
Ivana Mitrović (Elektroprivreda Srbije AD Beograd )
Abstrakt
Zasipanje hidroakumulacija u stručnoj raksi i literaturi smatra se potencijalno velikim problemom i pretnjom po održivo upravljanje hidroakumulacijama i očuvanje njihove korisne zapremine. Ako se ima u vidu značaj korisne zapremine hidroakumulacija za osiguranje vodosnabdevanja stanovništva, osiguranje proizvodnje električne energije, očuvanje funkcionalnosti plovnih puteva, smanjenje rizika od poplava i druge namene uključujući i ciljeve održivog razvoja neposredno sledi da njihovo upravljanje odražava stepen odgovornosti društva prema budućnosti. Imajući u vidu da je najveći deo potencijala za izgradnju akumulacija za hidroelektrane uglavnom iskorišćen i da je zapunjavanje akumulacija prirodan proces onda se posebna pažnja mora posvetiti njihovom održivom upravljanju. Motivacija za ovaj rad nastala je kao posledica uverenja autora da se ovoj problematici ne pridaje dovoljan značaj u stručnoj literaturi u Republici Srbiji obzirom na probleme koji mogu nastati u budućnosti. Rad se pretežno zasniva na istraživanju literature dostupne na internetu i u radovima sa stručnih skupova. Takođe se predlaže i ekonomski model za obezbeđivanje sredstava neophodnih za održivo upravljanje hidroakumulacijama.
Žarko Nestorović, Maja Đorđević Radulović, Vladimir Tomić (Elektroprivreda Srbije AD Beograd, Ogranak Đerdap)
Abstrakt
Određivanje radijusa lopatica radnog kola geodetskim metodama zasniva se na izravnanju rezultata merenja koordinata tačaka na obodu lopatica radnog kola i primeni metode najmanjih kvadrata kako bi se odredile nepoznate koordinate centra sfere definisane tačkama na obodu radnog kola. Merenje je vršeno pri zatvorenom i otvorenom položaju radnog kola u približno istim tačkama na obodu lopatice radnog kola. Metod najmanjih kvadrata primenjen na koordinate dobijene merenjem pokazao je visoku saglasnost pri proveri zazora radnog kola i obloge radnog kola. Primenjeni metod omogućava proveru odstupanja radijusa u odnosu na projektovanu vrednost. Merenja su vršena u okviru procesa revitalizacije agregata na HE Đerdap 1.
Aleksandar Stepanović, Principal Technical Associate (Research and Development Institute Lola Ltd, Kneza Višeslava 70a, 11000 Belgrade, Serbia)
Ivan Božić, PhD, Full Professor (University of Belgrade - Faculty of Mechanical Engineering, Laboratory for Research, Development, Testing, and Optimization of Hydropower Plants, 11000 Belgrade, Serbia)
Bogdan Ristić, teaching assistant (University of Belgrade - Faculty of Mechanical Engineering, Laboratory for Research, Development, Testing, and Optimization of Hydropower Plants, 11000 Belgrade, Serbia)
Ivan Vasović Maksimović, PhD, Senior Research Associate (Research and Development Institute Lola Ltd, Kneza Višeslava 70a, 11000 Belgrade, Serbia)
Abstrakt
Reliable and stable operations of hydropower units are among the main priorities in the functioning of hydropower plants in extremely dynamic and demanding contemporary electric power systems. Everything that causes deviation from the stated priorities needs to be properly analyzed and, if possible, eliminated. Pressure pulsations that appear in a hydraulic turbine can have an impact on an increase in hydraulic oscillations and mechanical vibrations, structural damage, instability of the power transmitted to the generator, and resonance, as well as on a decrease in the efficiency of the hydropower unit. Numerous phenomena that occur during the exchange of energy in the hydraulic turbine flow domain cause pressure pulsations. Understanding fluid flow dynamics around an isolated hydro profile is the first and essential stage for optimizing the performance and the design of all types of hydraulic turbines. This paper provides an additional contribution to the unsteady water flow numerical analysis of the isolated NACA0009 hydro profile, truncated to 90% of its original length, in order to check and confirm the induced pressure pulsations. The simulations were conducted for different attack angles of the profile under constant outlet pressure and inlet flow velocity, thus expanding the scope of analysis of pressure coefficients. Some of the numerical results were verified by the available experimental data and compared with other published results.
Žarko Nestorović, Maja Đorđević Radulović, Evica Šejnjanović (Elektroprivreda Srbije AD Beograd, Ogranak Đerdap)
Abstrakt
Određivanje saosnosti obrtnih delova turbina geodetskim metodama omogućava proveru saglasnosti centara različitih delova i sklopova. U okviru revitalizacije agregata na HE Đerdap 1 bilo je neophodno izvršavati proveru saglasnosti centara obloge radnog kola i ležišta lopatica donjeg prstena usmernog aparata na agreatima HE Đerdap 1. Metodologija određivanja saglasnosti centara se zasnivala na određivanju koordinata tačaka na oblozi radnog kola i ležišta lopatica donjeg prstena usmernog aparata u istom koordinatnom sistemu što je omogućeno formiranjem specijalne geodetske 2D mreže. Na osnovu koordinata tačaka obloge radnog kola i ležišta lopatica donjeg prstena usmernog aparata dobijenih izravnanjem rezultata geodetskih merenja određene su koordinate centara obloge radnog kola i ležišta lopatica donjeg prstena usmernog aparata. Rezltati su pokazali da odstpanja ova dva centra iznose manje od pola milimetra.
Valentino Stojkovski, Marjan Gavriloski (“Ss. Cyril & Methodius” University in Skopje, Faculty of Mechanical Engineering Skopje)
Aleksandar Levkoski (JSC Power Plants of North Macedonia)
Filip Stojkovski (Iskra Impuls Slovenia)
Abstrakt
Siphon systems, as critical elements of pressurized water distribution networks, are implemented wherever the hydraulic conveyance path is engineered to bypass or reduce the natural flow path. While highly efficient and widely applicable, such systems introduce complex and often concealed hydraulic conditions that require careful consideration during design and operation. In this study, a numerical model of a full-scale pressure siphon pipeline with a curved alignment was developed and the hydraulic behavior was evaluated through Computational Fluid Dynamics (CFD) analysis. Field inspections revealed material degradation and wall thinning within the pipeline after prolonged service under operational loads. By integrating wall-thickness measurements with visual assessment of damage morphology, the investigation characterizes the observed wear mechanisms and patterns. The CFD model correlates these wear patterns with flow-induced phenomena inherent to the siphon’s configuration, thereby clarifying the underlying cause of the observed deterioration. The insights gained from this research provide a design-oriented framework for mitigating damage in large-scale siphonic pipeline segments and offer guidance for future planning, modeling, and maintenance strategies in pressurized water distribution systems.